The Battery Pack Assembly MAC PAC is made up of Nickel metal-hydride (NiMH) battery cells, the assembly is comprised of 15 number of cells connected in series to generate 18VDC. The assembly is included with inbuilt safety thermostat connected in series with the battery circuit to protect the battery from functioning during high temper
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Flapper Valve 1.062 D .875 L with TPR Stem SIL BCG
Flapper Valve 1.062 D .875 L with TPR Stem SIL BCG is a flapper valve that is made up of a data sensitive silicone material with shore durometer value ranging of 35 to 45. It acts as a tight seal for regulating gas flow for patients. It basically allows flow of fresh gas to enter the inhalation valve and exit the exhalation valve, insp
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
O-ring - 34.59 ID 39.83 BCG OD 2.62W EPR 60 Duro
The O-ring is used to prevent the leakage of vapors from Breathing Circuit Gas (BCG) in an anesthesia delivery machine. A common cause of vapor leakage is an absent or damaged O-ring. This O-rings are used in Breathing Circuit Gas (BCG) system to prevent leakage of gases. It is the most common type of seal used in a wide range of stati
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
The O-ring is used to prevent the leakage of vapors from Breathing Circuit Gas (BCG) in an anesthesia delivery machine. A common cause of vapor leakage is the absent or damaged O-ring. It is used in the flow meter assembly of a simple anesthesia machine, there are tubes through which gases flow to the outlet. O-rings are fitted at the
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Bellows Sub Assembly - Adult ABA with Disk-Ring-Bumpers BCG
-
0229-1013-700
The Bellows Sub Assembly - Adult ABA with Disk-Ring-Bumpers BCG is used in an anesthesia delivery system, which provides a sophisticated ascending bellows type ventilation. This system helps by taking in ambient air, which can be enriched with oxygen from a cylinder. The bellow assembly contains bellows snapped to a disk, molded in str
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Keyboard Assembly English MAC 5000
-
421115-001, 421108-006
The Keyboard Assembly English MAC 5000 is a keyboard, which is an input device that is used to enter the patient’s demographics manually. The keyboard has alpha numeric keys and soft function keys made of a sealed elastomer. This keyboard has both writer control as well cursor control. Writer control would allow the user to edit or ent
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Printed circuit Board (PCB) Cam 14 Cable Interface Connector
The PCB Cam 14 Cable Interface Connector is a component in the acquisition module assembly. The acquisition module performs high resolution ECG data acquisition for use with host equipment. The module is intended to acquire analog ECG signals and digitalizes it and transmit the signal to a host unit. It is used in ECG analysis and exer
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
The CAM HD Assembly is a Data Acquisition Module. The measurement system contains the ECG amplifier module, a data acquisition module and a computer. The minute ECG signals from the patient are received by the electrodes and are sent to the acquisition module via lead wires. The acquisition module then amplifies, digitizes, and perform
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Service Kit PCA Power Board - Warmer - RoHS
Printed Circuit Board PCA Power Board - Warmer Kit is a service kit that is comprised of a PCA power board, label and stickers. The specially designed PCB assembly controls and monitors the voltage of the connected devices and the display board power of Infant Warmer™ incubators. The service parts are securely packaged in a high qualit
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment. -
Battery 11.1V 3S2P 18650 Li-Ion SMBUS
-
419068-005, 419068-004,  [...]
The rechargeable lithium ion (Li-Ion) battery pack is a specially designed module, for use in the CARESCAPE™ patient monitor system and other medical equipment as applicable. The module is comprised of inbuilt integrated circuits (IC), TI BQ2060 and Mitsumi MM1414CV. The integrated circuit BQ2060 measures available charge in the batter
[...]Add to Wish ListSign In & Add To CartSecond Opinion Approval NeededEnter your approval number and submit to add item(s) to cart.
Approval NumberPlease enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.Second Opinion Approval NeededSelect your approver's name and submit to add item(s) to your cart
Approver NamePlease Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Parts Identification Tool
Equipment Lookup
Need to know what equipment your part is compatible with?
Equipment search
Enter your equipment details below, and access the list of compatible parts